On-Line Operation
6-3
Notes: LADC only appears on the screen for units equipped with the Model A or C
Aggregate card.
The Excalibur Multirate DAP provides the transmit and receive levels for use as a
reference, not as an absolute value. Accuracy is dependent on the data pattern and line
conditions.
Press the Escape button to return to the Status submenu.
Table 6-1. Receive Level Insertion Loss Ranges
DDS Line Rate Insertion Loss Range Values
2.4 Kbps <7, <13, <18, <22, <27, <33, <38, <50
4.8 Kbps <7, <12, <16, <22, <27, <33, <39, <50
9.6 Kbps <5, <11, <16, <22, <27, <33, <37, <40
19.2 Kbps <4, <11, <16, <22, <28, <33, <39, <50
56 Kbps <4, <11, <17, <23, <29, <35, <42, <48, <50
72 Kbps (CC64) <3, <11, <17, <23, <29, <36, <42, <48, <50
Note: The insertion loss range values are defined as being less than the listed number,
but greater than the number listed to the immediate left.
4. Press the button beneath Dial. This parameter appears on the screen only for
units equipped with the Analog, Switched 56, or ISDN IDBU option. The screen
displays the Analog, Switched 56 or ISDN IDBU's current operating status. For
Analog IDBU, the display appears as follows:
Escape
TopL
S t a t u s M o d e
D A P D i a l S e r v e D i g t l >
L
9 . 6 C T L - 9 d B m R L - 1 7 d B m
Q = B e s t D i a l = N T s t = N